■  Home  ■  Products  ■  Sticks 900  ■  Sticks 900 C STR
Abbreviations keys

Abbreviation key

Media temperature

  • C = cryogenic temperature
  • A = ambient temperature

Pressure range

  • LP = low pressure (below 1 bar)
  • MP = medium pressure (up to 40/45/63 bar)
  • HP = high pressure (250 to 420 bar)
  • UHP = ultra-high pressure (420 to 1.000 bar)

Vacuum jacketing

  • No = not suitable for installation in vacuum-jacketed pipes
  • Std = for installation in vacuum-jacketed pipes
  • Opt = suitable for vacuum-jacketed pipes, vacuum flange as option

Function

  • GV = Globe valve
  • CV = Control valve
  • CHK = Check valve
  • STR = Strainer
  • OV = Overflow valve
  • RV = Relief valve

Actuation

  • M = manual
  • P = electro-pneumatic
  • PR = electro-pneumatic with IP regulator
  • E = electric
  • S = solenoid
  • SPR = spring-based
  • HY = hydraulic

 

We’re here to help

The desired specification not found yet?
Are you looking for something out of this website and the product catalog?
Then send us the specifications for your special requirement.

sales@stoehr-valves.de

We make Extremes happen.


Parameters: Sticks900_C_STR

DN PN End connection d x s x l Length Height ø Seat Drawing number Single inquiry
151816,0 x 1,0 x 10693301040-900Single inquiry
152516,0 x 1,0 x 10693302040-900.2.3Single inquiry
251028,0 x 1,5 x 251383302540-901Single inquiry
252528,0 x 1,5 x 251383302540-901.2.3Single inquiry
501054,0 x 2,0 x 502505804540-906Single inquiry

Technical Data

Technical DataTechnical Design
Service fluidsN2, O2, Ar, H2, He, NG*
Operating temp. fluid -196 °C (-269 °C) to +50 °C
Operating temp. enviroment -30 °C to +50 °C
Body material stainless steel
Seat sealing metal/PCTFE
Body sealing O-ring (Viton) He leakage rate to atmosphere 1*10-8 mbar*l/s
Surface treatment machined, ground, electro-polished or passivated**
Body shape straight or angle
Installation position horizontal in flow direction, bonnet on top, max. 30° vertical
Material certificates DIN EN 10204/3.1 AD2000-A4
Welding flange as standard for vacuum insulated tubes
Filter insert wire mesh pipe filter, nominal 40, 100, 30, 20, 10 oder 1 µ, Standard 40 µ

* All dangerous, toxic or acid fluids according to material compatibility.
**Surface treatment can be choosen according to customer specification. See product options