Sticks 900
Cryogenic filter
Sticks 900: filter unit with filter element made from stainless steel wire mesh. Optional sinter filter for vacuum insulation and cryogenic systems with extremely low heat inlet. For nitrogen, helium, hydrogen and other gases. Regenerative filter element. Standard wire mesh with 40 µ.The valve body is machined from one piece of solid stainless steel. Straight filter or angle filter configuration. End connections can be supplied in butt-welded execution or according to customer specification.
Series Sticks 900
Abbreviations keys
Abbreviation key
Media temperature
- C = cryogenic temperature
- A = ambient temperature
Pressure range
- LP = low pressure (below 1 bar)
- MP = medium pressure (up to 40/45/63 bar)
- HP = high pressure (250 to 420 bar)
- UHP = ultra-high pressure (420 to 1.000 bar)
Vacuum jacketing
- No = not suitable for installation in vacuum-jacketed pipes
- Std = for installation in vacuum-jacketed pipes
- Opt = suitable for vacuum-jacketed pipes, vacuum flange as option
Function
- GV = Globe valve
- CV = Control valve
- CHK = Check valve
- STR = Strainer
- OV = Overflow valve
- RV = Relief valve
Actuation
- M = manual
- P = electro-pneumatic
- PR = electro-pneumatic with IP regulator
- E = electric
- S = solenoid
- SPR = spring-based
- HY = hydraulic
Parameters: Sticks900_C_STR
DN | PN | End connection d x s x l | Length | Height | ø Seat | Drawing number | Single inquiry |
---|---|---|---|---|---|---|---|
15 | 18 | 16,0 x 1,0 x 10 | 69 | 330 | 10 | 40-900 | Single inquiry |
15 | 25 | 16,0 x 1,0 x 10 | 69 | 330 | 20 | 40-900.2.3 | Single inquiry |
25 | 10 | 28,0 x 1,5 x 25 | 138 | 330 | 25 | 40-901 | Single inquiry |
25 | 25 | 28,0 x 1,5 x 25 | 138 | 330 | 25 | 40-901.2.3 | Single inquiry |
50 | 10 | 54,0 x 2,0 x 50 | 250 | 580 | 45 | 40-906 | Single inquiry |
Technical Data
Technical Data | Technical Design |
---|---|
Service fluids | N2, O2, Ar, H2, He, NG* |
Operating temp. fluid | -196 °C (-269 °C) to +50 °C |
Operating temp. enviroment | -30 °C to +50 °C |
Body material | stainless steel |
Seat sealing | metal/PCTFE |
Body sealing | O-ring (Viton) He leakage rate to atmosphere 1*10-8 mbar*l/s |
Surface treatment | machined, ground, electro-polished or passivated** |
Body shape | straight or angle |
Installation position | horizontal in flow direction, bonnet on top, max. 30° vertical |
Material certificates | DIN EN 10204/3.1 AD2000-A4 |
Welding flange | as standard for vacuum insulated tubes |
Filter insert | wire mesh pipe filter, nominal 40, 100, 30, 20, 10 oder 1 µ, Standard 40 µ |
* All dangerous, toxic or acid fluids according to material compatibility.
**Surface treatment can be choosen according to customer specification. See product options