■  Home  ■  Products  ■  Sticks 900TD  ■  Sticks 900TD C GV M
Abbreviations keys

Abbreviation key

Media temperature

  • C = cryogenic temperature
  • A = ambient temperature

Pressure range

  • LP = low pressure (below 1 bar)
  • MP = medium pressure (up to 40/45/63 bar)
  • HP = high pressure (250 to 420 bar)
  • UHP = ultra-high pressure (420 to 1.000 bar)

Vacuum jacketing

  • No = not suitable for installation in vacuum-jacketed pipes
  • Std = for installation in vacuum-jacketed pipes
  • Opt = suitable for vacuum-jacketed pipes, vacuum flange as option

Function

  • GV = Globe valve
  • CV = Control valve
  • CHK = Check valve
  • STR = Strainer
  • OV = Overflow valve
  • RV = Relief valve

Actuation

  • M = manual
  • P = electro-pneumatic
  • PR = electro-pneumatic with IP regulator
  • E = electric
  • S = solenoid
  • SPR = spring-based
  • HY = hydraulic

 

We’re here to help

The desired specification not found yet?
Are you looking for something out of this website and the product catalog?
Then send us the specifications for your special requirement.

sales@stoehr-valves.de

We make Extremes happen.


Parameters: Sticks900TD_C_GV_M

DN PN End connection d x s x l Length Height Extension A ø Seat Kv-Value Drawing number Single inquiry
151816,0 x 1,0 x 1069413279101,8914-900.15.4Single inquiry
152516,0 x 1,0 x 1069437279101,8914-900.15.5Single inquiry
251028,0 x 1,5 x 25138495300257,0114-901.15.4Single inquiry
252528,0 x 1,9 x 25128548300257,0114-901.15.5Single inquiry
501054,0 x 2,0 x 502507805004525,114-906.15.4Single inquiry

Technical Data

Technical DataTechnical Design
Service fluidsN2, O2, Ar, H2, He, NG*
Operating temp. fluid -196 °C (-269 °C) to +50 °C
Operating temp. enviroment -30 °C to +50 °C
Body material stainless steel
Actuator hand wheel or pneumatic
Seat sealing metal/PCTFE seat leakage rate 1*10-6 mbar*l/s
Body sealing O-ring (Viton) He leakage rate to atmosphere 1*10-8 mbar*l/s
Stem sealing stainless steel bellow physically tight
2nd stem sealing safety-O-ring (Viton)
Surface treatment machined, ground, electro-polished or passivated**
Body shape straight or angle
Installation position unlimited in all directions
Material certificates DIN EN 10204/3.1 AD2000-A4
Welding flange as standard for vacuum insulated tubes

* All dangerous, toxic or acid fluids according to material compatibility.
**Surface treatment can be choosen according to customer specification. See product options