■  Home  ■  Products  ■  Frees 1200TD  ■  Frees 1200TD C GV P
Abbreviations keys

Abbreviation key

Media temperature

  • C = cryogenic temperature
  • A = ambient temperature

Pressure range

  • LP = low pressure (below 1 bar)
  • MP = medium pressure (up to 40/45/63 bar)
  • HP = high pressure (250 to 420 bar)
  • UHP = ultra-high pressure (420 to 1.000 bar)

Vacuum jacketing

  • No = not suitable for installation in vacuum-jacketed pipes
  • Std = for installation in vacuum-jacketed pipes
  • Opt = suitable for vacuum-jacketed pipes, vacuum flange as option

Function

  • GV = Globe valve
  • CV = Control valve
  • CHK = Check valve
  • STR = Strainer
  • OV = Overflow valve
  • RV = Relief valve

Actuation

  • M = manual
  • P = electro-pneumatic
  • PR = electro-pneumatic with IP regulator
  • E = electric
  • S = solenoid
  • SPR = spring-based
  • HY = hydraulic

 

We’re here to help

The desired specification not found yet?
Are you looking for something out of this website and the product catalog?
Then send us the specifications for your special requirement.

sales@stoehr-valves.de

We make Extremes happen.


Parameters: Frees1200TD_C_GV_P

DN PN End connection d x s x l Length Height Extension A ø Seat Kv-Value Drawing number Single inquiry
102517,2 x 1,6 x 25180758450151,518-1200.15.1Single inquiry
152521,3 x 1,6 x 25180758450153,418-1201.15.1Single inquiry
202526,9 x 1,6 x 25180850450255,818-1202.15.1Single inquiry
252533,7 x 2,0 x 25180850450259,118-1203.15.1Single inquiry
322542,4 x 2,0 x 30230950600451618-1204.15.1Single inquiry
402548,3 x 2,0 x 35230950600452518-1205.15.1Single inquiry
502560,3 x 2,0 x 502509506004532,318-1206.15.1Single inquiry

Technical Data

Technical DataTechnical Design
Service fluidsN2, O2, Ar, H2, He, NG*
Operating temp. fluid -196 °C (-269 °C) bis +50 °C
Operating temp. enviroment -30 °C to +50 °C
Body material stainless steel
Actuator piston actuator, pneumatic single-acting
Seat sealing metal/PCTFE seat leakage rate 1*10-6 mbar*l/s
Seat sealing metal/PTFE seat leakage rate 1*10-6 mbar*l/s
Seat sealing metal/metal seat leakage rate 1*10-3 mbar*l/s
Body sealing metal seal ring He leakage rate to atmosphere 1*10-8 mbar*l/s
Stem sealing stainless steel bellow physically tight
2nd stem sealing safety-O-ring (Viton)
Surface treatment machined, ground, electro-polished or passivated**
Body shape straight or angle
Installation position optional (horizontal or upside-down)
Material certificates DIN EN 10204/3.1 AD2000-A4
Actuating pressure 6 + 0,5/-0,0 bar, dry compressed air or nitrogen
End connect. for actuating air female thread G 1/8" G 1/4"
Welding flange optional for vacuum-jacketed pipes
Safety position normally closed (NC) or normally open (NO)

* All dangerous, toxic or acid fluids according to material compatibility.
**Surface treatment can be choosen according to customer specification. See product options