Series Blasts 2600
Abbreviations keys
Abbreviation key
Media temperature
- C = cryogenic temperature
- A = ambient temperature
Pressure range
- LP = low pressure (below 1 bar)
- MP = medium pressure (up to 40/45/63 bar)
- HP = high pressure (250 to 420 bar)
- UHP = ultra-high pressure (420 to 1.000 bar)
Vacuum jacketing
- No = not suitable for installation in vacuum-jacketed pipes
- Std = for installation in vacuum-jacketed pipes
- Opt = suitable for vacuum-jacketed pipes, vacuum flange as option
Function
- GV = Globe valve
- CV = Control valve
- CHK = Check valve
- STR = Strainer
- OV = Overflow valve
- RV = Relief valve
Actuation
- M = manual
- P = electro-pneumatic
- PR = electro-pneumatic with IP regulator
- E = electric
- S = solenoid
- SPR = spring-based
- HY = hydraulic
Parameters: Blasts2600_A_RV_SPR-1250
DN | End connection | L 1 | L 2 | ø outflow | Drawing number | Single inquiry |
---|---|---|---|---|---|---|
5/8 | KF 16 | 8,5 | 25,5 | 24,6 | 26.39.05 | Single inquiry |
4/5 | KF 25 | 9 | 26,5 | 40 | 26.39.06 | Single inquiry |
4/5 | KF 40 | 10 | 35,5 | 83,5 | 26.39.07 | Single inquiry |
50 | KF 50 | 11 | 44 | 182,5 | 26.39.08 | Single inquiry |
Technical Data
Technical Data | Technical Design |
---|---|
Service fluids | N2, O2, H2, He, Ar, vacuum etc. * |
Operating temp. fluid | 20 °C |
Operating temp. enviroment | -30 °C to +50 °C |
Body material | stainless steel |
Response pressure | 20 - 1250 mbar ** |
Seat sealing | soft seal (Viton) |
Body sealing | metal/soft seal (Viton) |
Tightness to outside | to atmosphere 1*10-3 mbar*l/s |
Installation position | opt. preferably with horizontal flow direction |
* All dangerous, toxic or acid fluids according to material compatibility.
**Surface treatment can be choosen according to customer specification. See product options