■  Home  ■  Products  ■  Novis 500  ■  Novis 500 C GV M
Abbreviations keys

Abbreviation key

Media temperature

  • C = cryogenic temperature
  • A = ambient temperature

Pressure range

  • LP = low pressure (below 1 bar)
  • MP = medium pressure (up to 40/45/63 bar)
  • HP = high pressure (250 to 420 bar)
  • UHP = ultra-high pressure (>> 420 to 1.000 bar)

Vacuum jacketing

  • No = not suitable for installation in vacuum-jacketed pipes
  • Std = for installation in vacuum-jacketed pipes
  • Opt = suitable for vacuum-jacketed pipes, vacuum flange as option

Function

  • GV = Globe valve
  • CV = Control valve
  • CHK = Check valve
  • STR = Strainer
  • OV = Overflow valve
  • RV = Relief valve

Actuation

  • M = manual
  • P = electro-pneumatic
  • PR = electro-pneumatic with IP regulator
  • E = electric
  • S = solenoid
  • SPR = spring-based

 

We’re here to help

The desired specification not found yet?
Are you looking for something out of this website and the product catalog?
Then send us the specifications for your special requirement.

sales@stoehr-valves.de

We make Extremes happen.


Parameters: Novis500_C_GV_M

DN PN End connection d x s Length Height Total length Weight Kvs-Value Drawing number Single inquiry
152533,7 x 2,0357420~ 5772,9 kg14,614-501Single inquiry
252533,7 x 2,0257420~ 4772,8 kg14,614-503Single inquiry

Technical Data

Technical DataTechnical Design
Service fluidsSuitable for aggressive, neutral, gaseous or liquid media; specially optimised for gases down to cryogenic temperatures (77 K / -196 °C); not for Oxygen use!
Operating temp. fluid -196 °C to +50 °C (77 K to 323 K)
Operating temp. enviroment -20 °C to +50 °C (253 K to 333 K)
Body material Stainless steel 1.4541
Actuator manual handwheel
Valve typ Globe valve
Cone shut-off cone
Connection type welding end acc. to ISO 1127
Seat sealing PCTFE / metal
Body sealing PCTFE seal ring
Stem sealing PTFE packing gland
Body shape body housing in Y-form with suitable stem extension
Tightness at seat 1*10-6 mbar*l/s
Tightness to outside 1*10-3 mbar*l/s
Installation position vertical, handwheel at top, tilt of angle max. 30° to the side

* All dangerous, toxic or acid fluids according to material compatibility.
**Surface treatment can be choosen according to customer specification. See product options