■  Home  ■  Products  ■  Axius 1400  ■  Axius 1400 C GV P
Abbreviations keys

Abbreviation key

Media temperature

  • C = cryogenic temperature
  • A = ambient temperature

Pressure range

  • LP = low pressure (below 1 bar)
  • MP = medium pressure (up to 40/45/63 bar)
  • HP = high pressure (250 to 420 bar)
  • UHP = ultra-high pressure (420 to 1.000 bar)

Vacuum jacketing

  • No = not suitable for installation in vacuum-jacketed pipes
  • Std = for installation in vacuum-jacketed pipes
  • Opt = suitable for vacuum-jacketed pipes, vacuum flange as option

Function

  • GV = Globe valve
  • CV = Control valve
  • CHK = Check valve
  • STR = Strainer
  • OV = Overflow valve
  • RV = Relief valve

Actuation

  • M = manual
  • P = electro-pneumatic
  • PR = electro-pneumatic with IP regulator
  • E = electric
  • S = solenoid
  • SPR = spring-based
  • HY = hydraulic

 

We’re here to help

The desired specification not found yet?
Are you looking for something out of this website and the product catalog?
Then send us the specifications for your special requirement.

sales@stoehr-valves.de

We make Extremes happen.


Parameters: Axius1400_C_GV_P

DN PN Media temperature Function Actuation Drawing number Single inquiry
6 – 80up to 420ampientGlobe valvepneumatic (Air)18-140XSingle inquiry
6 – 80up to 420cryogenicGlobe Valvepneumatic (GHe)18-140X.13Single inquiry

Technical Data

Technical DataTechnical Design
Service fluidsN2, O2, Ar, H2, He, NG*
Operating temp. fluid -196 °C (-269 °C) to +50 °C
Operating temp. enviroment -259 °C to +50 °C
Body material stainless steel
Actuator bellow actuated, pneumatic single-acting
Seat sealing metal/PCTFE seat leakage rate 1*10-6 mbar*l/s
Seat sealing metal/copper seat leakage rate at seat 1*10-3 mbar*l/s
Body sealing hermetically tight, He leakage rate to atmosphere 1*10-8 mbar*l/s
Stem sealing stainless steel bellow
Surface treatment machined, ground, electro-polished or passivated**
Body shape straight-through
Tightness at seat 1*10-3 mbar*l/s
Installation position any position, installation within the cryogenic medium tank or within vacuum space possible
Material certificates DIN EN 10204/3.1 AD2000-A4
Actuating pressure 6 + 0,5/-0,0 bar, dry compressed air or resp. He gas
End connect. for actuating air female thread G 1/8"
Safety position normally closed (NC) or normally open (NO)

* All dangerous, toxic or acid fluids according to material compatibility.
**Surface treatment can be choosen according to customer specification. See product options