UHP 800
Manual globe valve
UHP 800: Globe valve for gaseous media, primarily hydrogen, at ambient temperatures for very high pressures of up to 800 bar. Housing is optionally available in straight or angle body type. The valve is sealed to the outside using stuffing box packing. Adjusting forces can be transmitted by a gear-supported hand wheel (not illustrated) or by means of a ratchet at a standardized connection. Installation position preferably horizontal. Pipe connection according to customer requirements. Compatible with NAMUR limit switches, and pneumatic actuator available if required.
Optionally available with pneumatic actuator.
Parameters: UHP800_A_GV_M
DN | PN | Body type | Drawing number | Single inquiry |
---|---|---|---|---|
10 | 800 | straight | 22-957 | Single inquiry |
10 | 800 | angle | 22-958 | Single inquiry |
10 | 800 | straight | 22-959 | Single inquiry |
10 | 800 | angle | 22-960 | Single inquiry |
Technical Data
Technical Data | Technical Design |
---|---|
Service fluids | N2, NG*, preferably H2 |
Operating temp. fluid | -196 °C (-269 °C) to +50 °C |
Operating temp. enviroment | -259 °C to +50 °C or -30 °C to +50 °C |
Body material | stainless steel |
Actuator | handwheel or ratchet lever, alternatively pneumatic actuator |
Seat sealing | metal/PCTFE seat leakage rate 1*10-6 mbar*l/s |
Seat sealing | metal/copper seat leakage rate at seat 1*10-3 mbar*l/s |
Body sealing | He leakage rate to atmosphere 1*10-8 mbar*l/s |
Stem sealing | Gland packing |
Surface treatment | machined, ground, electro-polished or passivated** |
Body shape | straight or angle |
Installation position | any position, preferred with actuator on top |
Material certificates | DIN EN 10204/3.1 AD2000-A4 |
Actuating pressure | 6 + 0,5/-0,0 bar, dry compressed air or resp. He gas |
End connect. for actuating air | female thread G 1/8" |
Safety position | normally closed (NC) or normally open (NO) |
* All dangerous, toxic or acid fluids according to material compatibility.
**Surface treatment can be choosen according to customer specification. See product options